Watson Product Search Search None of the above, continue with my search Errors in logs attributed to a snapshot view update vob_ver_construct_cltxt_prep_suf; 1168360; vob_server(1251): Error: unable to create directory c/cdft/40: No The response I got was that probelm might be due to SAMBA which is not supported by Rational. During checkout ClearCase is copying the file from the cleartext pool into that directory. Two solutions exist: 1) Create a new view with correct permission. 2) Add a group to the existiong view. this contact form

Cause Possible cause for Symptom 1 above: There are multiple reasons for this error: The file is located inside a directory. If the issue is related to the view storage area, try correcting the protections on the view storage directory using operating system commands and functionality. It works divfferent for views stored on PC). This is the accepted answer. https://www.ibm.com/developerworks/community/forums/thread.jspa?threadID=75210

The key to the errors are the lines: Error: unable to create directory c/cdft/40: No such file or directory This issue can also be caused by running out of space in Turns out it wasn't server-side at all! This error can also occur if the "ClearCase Administrator" group owns the VOB.

All views located on a specific machine or machines are affected. Symptom Attempts to cat, type, or more an element version results in the following error: Incorrect function The following errors may also be reported in the ClearCase logs: In the MVFS Related information About read-only views Cross reference information Segment Product Component Platform Version Edition Software Development Rational ClearCase Permissions Document information More support for: Rational ClearCase Permissions Software version: 7.0, 7.0.0.1, An element can be created , checked-in and checked out for first time.

Watson Product Search Search None of the above, continue with my search About the error Checked out version, but could not copy data to in view Checked out version; but This requier root to set the correct flags. If the file can be read, it means that the VOB storage permissions are OK. http://www-01.ibm.com/support/docview.wss?uid=swg21168360 If the file cannot be read, it cannot be copied.

What is wrong or where should I continue my search? Watson Product Search Search None of the above, continue with my search Incorrect function error reading ClearCase versions incorrect function; interop; cat; type; list; dir; more; 1126427; copy Technote (troubleshooting) Problem(Abstract) Resolving the problem Solution 1 From the root of the VOB storage directory .vbs tree, navigate to the c\cdft subdirectory. The same problem exists if I use another view.

I noticed one more strange behaviour. Best regards, Rune <============================================================ To unsubscribe, send email to [email protected] and put these words in the message body: unsubscribe cciug ============================================================> <============================================================ To unsubscribe, send email to [email protected] and put these Correct the condition, then uncheckout and re-checkout the element. Here are the details of my setup: TeamCity Professional Version 4.5.5 (build 9103) TeamCity is using the my user account for its Build Agent.

Similar behavior will result from improper interop account setup for Windows users accessing UNIX (or Linux) VOBs. http://netfiscal.com/error-unable/error-unable-to-load-shared-object-rjava-dll.html Correct the condition, then uncheckout and re-checkout the element. The user is a member of the parent directories group but this is not set as ClearCase primary group. It's strange to me that the web service needs these permissions.

Also, someone else with ClearCase experience on this list might respond as well. Check the permissions on the source container. Solution 1 Reprotect the element with the cleartool protect -chown -chgrp -chmod command; refer to technote 1211784 that discusses protection commands and utilities used with ClearCase. navigate here You can obtain this by adding the following to your smb.conf somewhere in the global section: debug level = 5 This is not the cleanest way to handle this, but it

Unanswered question This question has not been answered yet. When I run a checkvob -pool no problems are reported. If the snapshot update still fails, revert the cleartext pools back to the original configuration before the fix applied and check your Samba, TAS or NAS settings (if in use) as

Is it possible to have 3 real numbers that have both their sum and product equal to 1?

Submit feedback to IBM Support 1-800-IBM-7378 (USA) Directory of worldwide contacts Contact Privacy Terms of use Accessibility Skip to content Follow: RSS Twitter Adventures in SCM One person, many challenges. Symptom Attempts to update a snapshot view results in the following error: cleartool: Error: Unable to load "". Resolving the problem Resolution options for Symptom 1: If the issue is related to permissions on the directory element, run the cleartool protect command to add the correct privileges. jetbrains.buildServer.vcs.VcsException: java.io.IOException: cleartool: Error: Operation "get cleartext" failed: Permission denied.

vobrpc_server(7412): Error: Vob server operation "Create Container" failed. Best regards, Rune <============================================================ To unsubscribe, send email to [email protected] and put these words in the message body: unsubscribe cciug ============================================================> <============================================================ To unsubscribe, send email to [email protected] and put these Cause 1 Misprotection of the element or the share permissions are incorrect for the VOB storage. http://netfiscal.com/error-unable/error-unable-to-initialize-civil-3d-object-model.html Diagnosing the problem Review the ClearCase Command Reference Guide on the topic of mkeltype (cleartool man mkeltype) for more information regarding the element types defined by ClearCase.

Note: This account should be registered to VOB owner or an account whose primary group is the VOBs primary group list. Cause The VOB is using a custom type manager and: The client does not have this custom type manager configured on the host. Cause 6 This has been seen to occur when two views were pointing to the same global path where an attempt to copy an element from one of the views reports the .idenity directory contain information of the views UID, GID, and secondary groups.

How to respond to a ridiculous request from a senior colleague? Problem was reported to Rational. Additional information may be available in the vob_log on host "" The vob_log will report: vob_server(1251): Error: Unable to create container /c/cdft/: No such file or directory vob_server(1251): Error: unable to End dir "".

Should I find punctures by immersing inner tube in water or hearing brezze or feeling breeze or how else? Symptom As stated in IBM Rational ClearCase Administrator's Guide: "To avoid VOB and view access permission problems, you must configure the NFS client to log on using user and group names Document information More support for: Rational ClearCase Interop Software version: 7.0, 2002.05.00, 2003.06.00 Operating system(s): AIX, HP-UX, IRIX, Linux, Solaris, Windows Reference #: 1126427 Modified date: 04 December 2012 Site availability Review the ClearCase Command Reference Guide on the topic of type_manager ( cleartool man type_manager) for more information.

Solution 3 Confirm that the interop configuration is correct, refer to technote 1142762 for guidance. Submit feedback to IBM Support 1-800-IBM-7378 (USA) Directory of worldwide contacts Contact Privacy Terms of use Accessibility United States English English IBM® Site map IBM IBM Support Check here to Quite a challenge, it was… Helpful link: Determine if a UNIX or Linux application is 32-bit or 64-bit Share this:TwitterFacebookLike this:Like Loading... Since I did not get much help from CCIUG and FAQs I am posting this message to SAMBA-TECHNICAL news group.

The following list of possible causes should be evaluated and their solutions matched below to resolve the specific issue. Severalcompress algoritm is used for different file types. Submit feedback to IBM Support 1-800-IBM-7378 (USA) Directory of worldwide contacts Contact Privacy Terms of use Accessibility United States English English IBM® Site map IBM IBM Support Check here to Why are Stormtroopers stationed outside the Death Star near the turbolaser batteries adjacent to Bay 327?

The *.vgs contains among other two direcories called 'd', and 'c'. Note: A type manager is used to manage the contents of element versions. This has been seen to occur following a power outage. I have some follow up questions: 1.